Restart a specific SCAN listener
Check current scan listener status:
$ srvctl status scan_listener
SCAN Listener LISTENER_SCAN1 is enabled
SCAN listener LISTENER_SCAN1 is running on node grac2
SCAN Listener LISTENER_SCAN2 is enabled
SCAN listener LISTENER_SCAN2 is not running
SCAN Listener LISTENER_SCAN3 is enabled
SCAN listener LISTENER_SCAN3 is running on node grac2
Restart scan Listener LISTENER_SCAN2:
$ srvctl start scan_listener -i 2
Verify new SCAN listener status:
$ srvctl status scan_listener
SCAN Listener LISTENER_SCAN1 is enabled
SCAN listener LISTENER_SCAN1 is running on node grac2
SCAN Listener LISTENER_SCAN2 is enabled
SCAN listener LISTENER_SCAN2 is running on node grac1
SCAN Listener LISTENER_SCAN3 is enabled
SCAN listener LISTENER_SCAN3 is running on node grac2
Hi Helmut,
Your blog is very useful !
Thanks
Slim
very useful blog
Nice blog and guided very well….